10
Refitting the cabling into the housing
1
2
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Remove the protection plate.
Action
Insert the cabling carefully into the housing and
out at the axis-3 joint.
Refit the cable bracket with the two screws.
© Copyright 2021 ABB. All rights reserved.
5.3.5 Replacing the axis-4 cabling
Note
xx2100000301
Note
xx2100000345
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (4
pcs).
Tightening torque: 0.8 Nm
xx2000002078