ABB CRB 15000 Product Manual page 375

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

2
Disconnecting the axis-1 joint unit cabling
1
2
3
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Tilt the base on to its side and remove the bottom
cover by removing the attachment screws.
Action
Cut the cable ties.
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J1.DC+
J1.DC-
J1.CS
J1.CP
© Copyright 2021 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the base
Continued
Note
xx2000002007
Note
xx2000002012
xx2000002011
xx2000002010
Continues on next page