5 Repair
5.4.3 Replacing the tubular
Continued
2
3
4
5
Continues on next page
288
Action
Remove the cover screws.
CAUTION
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
Open the cover and cut the cable tie that holds
the brake release cable.
Disconnect the brake release connector from the
drive board.
Remove the cover.