ABB CRB 15000 Product Manual page 245

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

Spare part
Lower arm
Required tools and equipment
Equipment
Guide pin, M4x120
Standard toolkit
Required consumables
Consumable
Grease
Cleaning agent
Flange sealant
Cable ties
O-ring
O-ring
Removing the lower arm
Use these procedures to remove the lower arm.
Preparations before removing the lower arm
1
2
Removing the lower arm covers
1
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Jog the robot to the synchronization position.
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
© Copyright 2021 ABB. All rights reserved.
5.4.1 Replacing the lower arm
Article number
Note
3HAC073948-001
Article number
Note
3HAC077786-001
Always use guide pins in pairs.
-
Content is defined in section
Standard toolkit on page
Article number
Note
3HAC042536-001
Shell Gadus S2
-
Isopropanol
-
Loctite 574
-
3HAC061327-047
Cover for axis 2/3
Replace if damaged.
3HAC061327-044
Lower arm, inner cover. 1 pcs /
cover.
Replace if damaged.
Note
Note
5 Repair
Continued
625.