5 Repair
5.3.3 Replacing the axis-2 cabling
Continued
3
4
5
6
Continues on next page
144
Action
Cut the cable tie at the drive board.
Remove the protection plate.
Remove the cable support from the drive board
by removing the attachment screws.
Disconnect the two connectors from the torque
sensor board.
TQ.A
TQ.B
© Copyright 2021 ABB. All rights reserved.
Note
xx2000002058
xx2100000301
xx2000002055
xx2000002053
Product manual - CRB 15000