Fastening the cabling between the lower and upper arm
1
2
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Refit the cable bracket with the four screws.
Action
Secure the cabling with the cable tie.
Connect the functional earth cable with the screw.
© Copyright 2021 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing
Continued
Note
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (4
pcs).
Tightening torque: 0.8 Nm
xx2000001966
Note
Cable ties
xx2000001965
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (1
pcs).
Tightening torque: 0.8 Nm
xx2000001964