ABB CRB 15000 Product Manual page 557

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

2
3
4
Removing the axis-5 joint unit
1
Product manual - CRB 15000
3HAC077389-001 Revision: A
5.6.5 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Action
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J5/6.DC+
J5/6.DC-
J5/6.CS
J5/6.CP
Disconnect the connectors from the drive board.
D4/5.X1
D5.DC+
D5.DC-
D4/5.X4
D5.X2
D4/5.X5
Use tweezers, if needed.
Action
Fit the lifting aid to the joint unit, on the torque
sensor side.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
© Copyright 2021 ABB. All rights reserved.
5 Repair
Continued
Note
xx2000002136
xx2000002137
Tweezers
xx2000002138
Note
Lifting aid: 3HAC077789-001
Screws: M3x12 (4 pcs)
xx2000002139
Continues on next page
557

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents