ABB CRB 15000 Product Manual page 226

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.3.7 Replacing the axis-6 cabling
Continued
3
4
5
Concluding procedure
1
226
Action
Fit the connectors to the cable bracket and secure
the connectors with two cable ties.
Refit the cable bracket with the screw.
Refit and secure the tool flange with screws and
washers.
Action
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 2021 ABB. All rights reserved.
Note
Cable ties (2 pcs)
xx2000002157
Hex socket head cap screw: M3x20
12.9 Gleitmo 603+Geomet 500 (1
pcs)
Tightening torque: 0.8 Nm.
xx2000002156
Hex socket head cap screw: M3x12
12.9 Gleitmo 603+Geomet 500 (10
pcs)
Spring washer: 7x3.2x0.6 Steel (10
pcs)
Tightening torque: 1.8 Nm.
xx2000002155
Note
Product manual - CRB 15000
3HAC077389-001 Revision: A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents