Product manual - CRB 15000
3HAC077389-001 Revision: A
5.6.5 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Action
Place the cabling at the slot before refitting the
joint unit.
Fit the joint unit to the tilt, aligning the pin with the
pin hole.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Secure the joint unit with new attachment screws.
© Copyright 2021 ABB. All rights reserved.
5 Repair
Continued
Note
xx2100000041
xx2100000285
xx2000002142
Hex socket head cap flange screw
with glue: 3HAB3413-330
M3x30, 12 pcs
Always use new screws when refit-
ting a joint unit. If ordering a new
joint unit spare part, new screws
are included.
xx2100000333
Continues on next page