5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
2
Disconnecting the axis-1 joint unit cabling
1
2
3
Continues on next page
116
Action
Tilt the base on to its side and remove the bottom
cover by removing the attachment screws.
Action
Cut the cable ties.
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J1.DC+
J1.DC-
J1.CS
J1.CP