ABB CRB 15000 Product Manual page 215

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

2
3
4
5
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
CAUTION
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
Loosen the tool flange and remove the cable
bracket by removing the screw.
Cut the cable ties.
Disconnect the CP/CS connectors from the drive
board and remove the tool flange.
© Copyright 2021 ABB. All rights reserved.
5.3.7 Replacing the axis-6 cabling
Note
xx2000002156
xx2000002157
xx2000002158
Continues on next page
5 Repair
Continued
215