5 Repair
5.3.5 Replacing the axis-4 cabling
Continued
4
Concluding procedure
1
192
Action
Refit the cover with the four screws.
Action
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 2021 ABB. All rights reserved.
Note
Hex socket head cap screw: M3x30
12.9 Gleitmo 603+Geomet 500 (4
pcs)
Tightening torque: 0.45 Nm
xx2000002021
Note
Product manual - CRB 15000
3HAC077389-001 Revision: A