2
3
Connecting the tubular cabling
1
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Refit the inner plate with the screws.
Refit the cover with the four screws.
Action
Reconnect the connectors to the drive board.
•
D3/4.DC+ to DC+
•
D3/4.DC- to Ground
•
D3/4.X2 to X2
© Copyright 2021 ABB. All rights reserved.
5.3.5 Replacing the axis-4 cabling
Note
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (4
pcs).
Tightening torque: 1.4 Nm
xx2000002076
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (4
pcs).
Tightening torque: 0.45 Nm
xx2000002075
Note
xx2000002120
Continues on next page
5 Repair
Continued
189