Required spare parts
Spare part
Cable harness, joint 3
Cable tie
Required tools and equipment
Equipment
Protection plate
Cable tie gun EVO7
Standard toolkit
Required consumables
Consumable
Cable ties
O-ring
O-ring
Grease
Removing the joint cabling
Use these procedures to remove the joint-3 cabling.
Preparations before removing the cabling
1
Product manual - CRB 15000
3HAC077389-001 Revision: A
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the CRB 15000 via myABB Business Portal,
www.abb.com/myABB.
Action
Jog the robot to the home position:
Axis 1: 0°
Axis 2: 0°
Axis 3: -80°
Axis 4: 0°
Axis 5: 0°
Axis 6: 0°
© Copyright 2021 ABB. All rights reserved.
5.3.4 Replacing the axis-3 cabling
Article number
Note
3HAC073207-001
Also order new Cable tie:
3HAC075545-001.
3HAC075545-001
For securing joint unit cable.
Article number
Note
3HAC077790-001
For protection of drive board
during cabling installation on joint
unit.
-
HellermannTyton 110-70084 or
similar
-
Content is defined in section
Standard toolkit on page
Article number
Note
-
3HAC061327-047
Cover for axis 2/3
Replace if damaged.
3HAC061327-044
Lower arm, inner cover. 1 pcs /
cover.
Replace if damaged.
3HAC042536-001
Shell Gadus S2
Note
5 Repair
Continued
625.
Continues on next page