ABB CRB 15000 Product Manual page 126

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
Refitting the swing
1
2
3
4
Continues on next page
126
Action
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the base
mounting surface, as pointed out in the figure.
Refit the swing to the base unit, aligning the pin
with the pin hole.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
Secure the swing with the attachment screws.
Pre-tighten the screws crosswise firstly.
Torque tighten all screws crosswise.
© Copyright 2021 ABB. All rights reserved.
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001990
xx2000001989
Hex socket head cap flange screw:
M4x25 (16 pcs)
xx2000001987
Tightening torque: 4.6 Nm.
Product manual - CRB 15000
3HAC077389-001 Revision: A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents