5 Repair
5.4.3 Replacing the tubular
Continued
Removing the tubular cover
1
Separating the cabling between the tubular and the tilt
1
2
3
Continues on next page
294
Action
Remove the cover by removing the six screws.
Dispose the screws. New screws must be used
when refitting the cover.
New screws are included in the spare part delivery
of the joint unit.
Action
Cut the cable ties, if needed.
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J4/5.DC+
J4/5.DC-
J4/5.CS
J4/5.CP