ABB CRB 15000 Product Manual page 353

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5
Disconnecting the tool flange functional earth cable
1
Removing the tool flange adapter
1
2
Product manual - CRB 15000
3HAC077389-001 Revision: A
5.4.5 Replacing the tool flange and axis-6 inner flange
Action
Disconnect the CP/CS connectors from the drive
board and remove the tool flange.
Action
Remove the functional earth cable by removing
the screw.
Action
Remove the tool flange adapter screws.
Press the adapter out of position by using two of
the attachment screws as removal tools.
© Copyright 2021 ABB. All rights reserved.
5 Repair
Continued
Note
xx2000002158
Note
xx2000002159
Note
xx2000002165
xx2000002166
Continues on next page