5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
3
Refitting the lower arm covers
1
2
Continues on next page
134
Action
Connect the functional earth cable with the screw.
Action
Wipe, lubricate and fit the o-ring to its groove.
Replace if damaged.
Refit the inner cover with four screws.
© Copyright 2021 ABB. All rights reserved.
Note
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (1
pcs).
Tightening torque: 0.8 Nm
xx2000001936
Note
O-ring: 3HAC061327-044
Grease: 3HAC042536-001 (Shell
Gadus S2)
xx2000001954
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (4
pcs)
Tightening torque: 1.4 Nm.
xx2000001930