5 Repair
5.6.5 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
2
3
4
Disconnecting the axis-5 joint unit cabling
1
Continues on next page
556
Action
CAUTION
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
Open the cover and cut the cable tie that holds
the brake release cable.
Disconnect the brake release connector from the
drive board.
Remove the cover.
Action
Cut the cable ties.
© Copyright 2021 ABB. All rights reserved.
Note
xx2000002133
xx2000002134
Note
xx2000002135
Product manual - CRB 15000