2
3
4
5
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Remove the cover screws.
CAUTION
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
Open the cover and cut the cable tie that holds
the brake release cable.
Disconnect the brake release connector from the
drive board.
Remove the cover.
© Copyright 2021 ABB. All rights reserved.
5.3.3 Replacing the axis-2 cabling
Note
xx2000001935
xx2000001931
xx2000001932
Continues on next page
5 Repair
Continued
139