2
3
4
Concluding procedure
1
Product manual - CRB 15000
3HAC077389-001 Revision: A
Action
Refit the inner covers with four screws each.
Snap the lower arm cover into place.
Secure the cover with four screws.
Action
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 2021 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the lower arm
Continued
Note
Hex socket head cap screw: M3x8
12.9 Gleitmo 603+Geomet 500 (8
pcs)
Tightening torque: 1.4 Nm.
xx2000001947
xx2000001930
Hex socket head cap screw: M3x16
12.9 Gleitmo 603+Geomet 500
(Black Oxide) (4 pcs)
Tightening torque: 0.45 Nm.
xx2000001929
Note
257