3HAC077389-001 Revision: A
Action
Reconnect the connectors to the drive board.
D1.X1 to X1
D1.DC+ to DC+
D1.DC- to Ground
D1.X4 to X4
D1.X2 to X2
D1.X5 to X5
DR.X8 to X8
Connect the connectors to each other and snap
them to the cable holders.
J1.DC+ to J1.DC+
J1.DC- to J1.DC-
J1.CS to J1.CS
J1.CP to J1.CP
Secure the cables for functional earth and protect-
ive earth with a screw.
© Copyright 2021 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the base
Continued
Note
xx2000002009
xx2000002010
Hex socket head cap screw: M3x6
(1 pcs).
Tightening torque: 0.8 Nm.
xx2000002011