5 Repair
5.4.6 Replacing the arm-side interface
Continued
Refitting the arm-side interface
Use these procedures to refit the arm-side interface.
Refitting the arm-side interface
1
2
Continues on next page
360
Action
Fit the o-ring to its groove.
Replace if damaged.
Place the arm-side interface at mounting position
and reconnect the connectors.
ASI.DC+
ASI.DC-
ASI.X1
The correct orientation of the arm-side interface
is with the convex button in upper position.
Note
Do not leave the arm-side interface in location
without being secured with the attachment screws.
© Copyright 2021 ABB. All rights reserved.
Note
O-ring: 3HAC061327-051
xx2000002551
xx2100000335
xx2100000336