COPIER > DISPLAY > DENS
CHG-DC-K
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
D-K-TRGT
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Appropriate Target Value
D-CRNT-P
2
D-CRNT-S
2
DENS-Y-H
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Appropriate Target Value
DENS-M-H
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Appropriate Target Value
DENS-C-H
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Appropriate Target Value
Dspl Bk-color primary charge DC voltage
To display the latest primary charging DC voltage of Bk-color.
When decrease in density/fogging occurs
N/A (Display only)
-1500 to 0
V
-900 - 400
1
Dspl of Bk patch target density:ATR ctrl
To display the target density for Bk patch image created by ATR control.
When analyzing the cause of a problem
N/A (Display only)
0 to 1023
300 - 700
For R&D
For R&D
Dspl of Y-clr TD ratio log: ATR control
To display the latest 8 Y-toner density log data (TD ratio) detected by the ATR Sensor at ATR
control.
Sharp change in values may indicate open circuit/failure of ATR Sensor, whereas gradual change
in values may indicate failure in toner supply system.
When checking toner density in the Developing Assembly at low density or fogging deterioration
N/A (Display only)
0 to 255
20 - 230
Dspl of M-clr TD ratio log: ATR control
To display the latest 8 M-toner density log data (TD ratio) detected by the ATR Sensor at ATR
control.
Sharp change in values may indicate open circuit/failure of ATR Sensor, whereas gradual change
in values may indicate failure in toner supply system.
When checking toner density in the Developing Assembly at low density or fogging deterioration
N/A (Display only)
0 to 255
20 - 230
Dspl of C-clr TD ratio log: ATR control
To display the latest 8 C-toner density log data (TD ratio) detected by the ATR Sensor at ATR
control.
Sharp change in values may indicate open circuit/failure of ATR Sensor, whereas gradual change
in values may indicate failure in toner supply system.
When checking toner density in the Developing Assembly at low density or fogging deterioration
N/A (Display only)
0 to 255
20 - 230