Canon imageRUNNER ADVANCE C5500 Series Service Manual page 977

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > OPTION > IMG-FIX
FXST2-N2
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXST2-UH
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FN-ENTMP
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FLYING
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Set ITOP wait time in LL env: plain ppr
To set initial rotation time when plain paper 1 to 3 is fed with a room temperature of 18 deg C or
lower.
Increase the value when a fixing failure occurs.
When a fixing failure occurs in an low temperature environment
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 20
sec
0
1
Set ITOP wait time in LL env: heavy ppr
To set initial rotation time when heavy paper 1 to 7 is fed with a room temperature of 18 deg C or
lower.
Increase the value when a fixing failure occurs.
When a fixing failure occurs in an low temperature environment
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 30
sec
0
1
Set of Fixing Cooling Fan ON/OFF temp
To set the ON/OFF temperature of the Fixing Cooling Fan (Front/Rear).
Increase the value when a fixing failure occurs on the edge of small size paper, and decrease the
value when fixing offset occurs.
When fixing offset/fixing failure occurs on the edge of small size paper
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-4 to 4
-4: -15 deg C, -3: -13 deg C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C, 3:
+13 deg C, 4: +15 deg C
deg C
0
5
ON/OFF of flying start temperature ctrl
To set whether to execute flying start temperature control.
When 1 is set, flying start temperature control is not performed. Selecting 1 has an advantage over
selecting 0 in terms of the life of the Fixing Unit. However, selecting 1 does not always extend the
life.
When preferring to extend the life of the Fixing Unit
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When 1 is set, FCOT becomes longer.
0 to 1
0: ON, 1: OFF
0
963
8. Service Mode