Canon imageRUNNER ADVANCE C5500 Series Service Manual page 922

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > OPTION > FNC-SW
CDS-MEAP
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
CDS-UGW
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
LOCLFIRM
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
MC-FANSW
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
BXNUPLOG
2
Set to allow MEAP installation by admin
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to permit the user (administrator) to install MEAP applications and enable iR options
from CDS.
When 1 is set, Updater can be activated from Settings/Registration menu.
When allowing the administrator to install MEAP applications and enable iR options from CDS
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Disabled, 1: Enabled
1
CDS: Contents Delivery System
Set to allow firmware update from UGW
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to permit update of the firmware from the UGW server.
When "1: Enabled" is set, Updater accepts the operation from the UGW server in cooperation with
CDS.
When allowing update of the firmware from the UGW server
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Disabled, 1: Enabled
It differs according to the location.
CDS: Contents Delivery System
Set to allow firmware update by file
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to permit the user (administrator) to update the firmware from the remote UI using
a local file.
This update is executed as a measure for vulnerability in emergency situations.
When allowing the administrator to update the firmware using a file
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Disabled, 1: Enabled
1
Setting of Controller Fan speed
To set full speed/half speed to the Controller Fan 1 and 2 .
When 1 is set, the heat exhaust efficiency is increased.
- When HDD damage occurs multiple times
- When the machine is installed in a high temperature environment in which HDD damage is likely
to occur
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Half speed, 1: Full speed
0
[Not used]
908
8. Service Mode

Advertisement

Table of Contents
loading