Canon imageRUNNER ADVANCE C5500 Series Service Manual page 837

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

■ PASCAL
COPIER > ADJUST > PASCAL
OFST-P-Y
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
OFST-P-M
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
OFST-P-C
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
Y density adj at test print reading
To adjust the offset of Y-color test print reading signal at auto gradation adjustment (full
adjustment).
When replacing the Reader Controller PCB/clearing RAM data, enter the value of service label.
As the value is larger, the image after adjustment gets darker.
When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-128 to 128
According to the adjustment value of the Reader at factory shipment
1
M density adj at test print reading
To adjust the offset of M-color test print reading signal at auto gradation adjustment (full
adjustment).
When replacing the Reader Controller PCB/clearing RAM data, enter the value of service label.
As the value is larger, the image after adjustment gets darker.
When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-128 to 128
According to the adjustment value of the Reader at factory shipment
1
C density adj at test print reading
To adjust the offset of C-color test print reading signal at auto gradation adjustment (full
adjustment).
When replacing the Reader Controller PCB/clearing RAM data, enter the value of service label.
As the value is larger, the image after adjustment gets darker.
When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
After the setting value is changed, write the changed value in the service label.
-128 to 128
According to the adjustment value of the Reader at factory shipment
1
823
8. Service Mode