10-0001
-
A. Operation / B. Cause /
C. Remedy
10-0002
-
A. Operation / B. Cause /
C. Remedy
10-0003
-
A. Operation / B. Cause /
C. Remedy
10-0004
-
A. Operation / B. Cause /
C. Remedy
10-0006
-
A. Operation / B. Cause /
C. Remedy
10-0007
-
A. Operation / B. Cause /
C. Remedy
10-0017
-
A. Operation / B. Cause /
C. Remedy
10-0018
-
A. Operation / B. Cause /
C. Remedy
10-0019
-
A. Operation / B. Cause /
C. Remedy
10-0020
-
A. Operation / B. Cause /
C. Remedy
Toner Low (Black) alarm
Low toner was detected and UGW generated an alarm.
* Not displayed on service mode history due to the alarm being generated by UGW
Toner Low (Cyan) alarm
Low toner was detected and UGW generated an alarm.
* Not displayed on service mode history due to the alarm being generated by UGW
Toner Low (Magenta) alarm
Low toner was detected and UGW generated an alarm.
* Not displayed on service mode history due to the alarm being generated by UGW
Toner Low (Yellow) alarm
Low toner was detected and UGW generated an alarm.
* Not displayed on service mode history due to the alarm being generated by UGW
Patch Sensor error 1
Movement: Patch control (not to execute Dmax, real-time multiple tone control and ATR control)
Cause: P-wave intensity of LED was out of the specified range (soiled window, failure of the sensor)
Measures:
1. Clean the window of the Patch Sensor, and execute light intensity correction. (Turn OFF and
then ON the main power and execute the correction at warm-up rotation.)
2. Check the Guide Plate (soiling, etc.).
3. Check the operation of the Registration Shutter Solenoid (SL1).
4. Check the connector between the DC Controller PCB and the sensor.
5. Replace the Registration Patch Sensor Unit.
6. Replace the DC Controller PCB. (At this time, be sure to perform backup and restoration
according to the steps to be taken before/after replacing the DC Controller.)
Patch Sensor error 2
Movement: Patch control (not to execute Dmax, real-time multiple tone control and ATR control)
Cause: S-wave intensity of LED was out of the specified range (soiled window, failure of the sensor)
Measures:
1. Clean the window of the Patch Sensor, and execute light intensity correction. (Turn OFF and
then ON the main power and execute the correction at warm-up rotation.)
2. Check the Guide Plate (soiling, etc.).
3. Check the operation of the Registration Shutter Solenoid (SL1).
4. Check the connector between the DC Controller PCB and the sensor.
5. Replace the Registration Patch Sensor Unit.
6. Replace the DC Controller PCB. (At this time, be sure to perform backup and restoration
according to the steps to be taken before/after replacing the DC Controller.)
Toner (Y) prior delivery alarm
An alarm for requesting a prior delivery is sent to UGW as the value of Toner level detect value
has reached the value set in COPIER > OPTION > FNC-SW > T-DLV-CL/T-DLV2CL.
Toner (M) prior delivery alarm
An alarm for requesting a prior delivery is sent to UGW as the value of Toner level detect value
has reached the value set in COPIER > OPTION > FNC-SW > T-DLV-CL/T-DLV2CL.
Toner (C) prior delivery alarm
An alarm for requesting a prior delivery is sent to UGW as the value of Toner level detect value
has reached the value set in COPIER > OPTION > FNC-SW > T-DLV-CL/T-DLV2CL.
Toner (Bk) prior delivery alarm
An alarm for requesting a prior delivery is sent to UGW as the value of Toner level detect value
has reached the value set in COPIER > OPTION > FNC-SW > T-DLV-BK.
650
7. Error/Jam/Alarm