Canon imageRUNNER ADVANCE C5500 Series Service Manual page 929

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > OPTION > FNC-SW
SEND-SPD
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
2TR-TBLS
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
VER-CHNG
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
FAX-STR
1
CE-SW
1
LIMFNC-M
2
ON/OFF of SEND operation speed-up
To set whether to speed up the SEND operation.
Usually, speed of SEND/XBOX is increased by performing image conversion during SEND and
Scan.
Reading speed may decrease when scanning large size color original at high resolution or when
competing operation occurs with another job during scanning. Set 1 to keep the speed.
When failure with MEAP application occurs, set 1.
- When reading speed is decreased during SEND and Scan
- When failure with MEAP application occurs
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: ON, 1: OFF
0
Set sec transfer bias correction table
To set the secondary transfer bias correction table according to the paper to be used.
Since physical properties of paper are different for each location, use the table according to the
paper to be used.
When using paper for a location other than the intended one
Enter the setting value, and then press OK key.
0 to 4
0: According to the location, 1: For Japan, 2: For Europe, 3: For USA, 4: For Asia
0
Setting of firmware update operation
To set how to update firmware of PCB/option which has been installed/replaced by comparing the
version of it with the version stored in the Flash PCB of the Main Controller.
If combination of firmware versions of PCB/option stored in the Main Controller and the version in
PCB/option after installation/replacement is not appropriate (operation with the combination of
firmware versions has not yet been checked), failure where analysis is difficult may occur.
It is possible to check the firmware versions at the start of the machine, and automatically write
the firmware stored in the Main Controller in PCB/option collectively as needed.
When 0 is set, versions are not checked and firmware update is not performed. Therefore, it is
necessary to manually update the versions using a USB flash drive/SST.
When 1 is set, firmware is updated if the version in PCB/option is old. However, it is not updated
if the version is new or old and new versions are mixed.
When 2 is set, a compatible firmware (the version where operation has been checked) is written
from the Main Controller regardless of whether the version in PCB/option is old or new.
When installing/replacing PCB/option having firmware
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 2
0: Keep the current firmware version.
1: Update the firmware if the version in PCB/option is older than that stored in the Main controller.
If the version is new or old and new versions are mixed, firmware is not updated.
2: Update the firmware regardless of whether the version is old or new if the version in PCB/option
differs from that stored in the Main Controller.
1
When updating the firmware, the main menu is displayed on the Control Panel at startup and then
a message prompting to update firmware is displayed.
By pressing [Update], the machine reboots immediately and firmware is updated.
By pressing [Skip], it returns to the main menu. The message is displayed again at next startup.
[For customization]
[Reserve]
[For customization]
915
8. Service Mode

Advertisement

Table of Contents
loading

Table of Contents