COPIER > OPTION > FNC-SW
T-DLV-CL
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
JM-ERR-D
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
JM-ERR-R
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
ASLPMAX
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
YMC Tonr Cont prior dvry alm notice tmg
To set the toner level as the timing to notify the prior delivery alarm for the Y/M/C-color Toner
Container.
When changing the timing to notify the end of life according to the usage status
Enter the setting value, and then press OK key.
Since toner level is calculated based on the toner supply count, some errors may occur.
0 to 40
%
It differs according to the location.
COPIER> OPTION> FNC-SW> T-DLV-BK
1
Set of error display of 0CAx jam (DCON)
To set whether to display "0CAx" jam as the error "E996-0CAx".
In the case of a jam, log cannot be obtained depending on the timing.
By selecting 1 when the jam "0CAx" occurs, it is displayed as the error "E996-0CAx" so that the
log can be obtained.
When obtaining a log at the occurrence of 0CAx jam
Enter the setting value, and then press OK key.
0 to 1
0: Display as a jam, 1: Display as an error
0
COPIER> OPTION> FNC-SW> JM-ERR-R
Set of error display of 0071 jam (RCON)
To set whether to display 0071 jam as the error "E996-0071".
In the case of a jam, a log may not be able to be obtained depending on the timing.
By selecting 1 when the 0071 jam occurs, it is displayed as an error so that a log can be obtained.
When obtaining a log at the occurrence of 0071 jam
Enter the setting value, and then press OK key.
0 to 1
0: Display as a jam, 1: Display as an error
0
COPIER> OPTION> FNC-SW> JM-ERR-D
Set auto sleep shift time maximum value
Set auto sleep shift time maximum value.
Upon user's request
Enter the setting value, and then press OK key.
0 to 1
0: 4 hours, 1: 60 minutes
JP:0, USA:0, EUR:1, AU:0, CN:0, KR:0, TW:0, ASIA:0
914