COPIER > ADJUST > DENS
P-TG-Y
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Additional Functions
Mode
P-TG-M
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Additional Functions
Mode
P-TG-C
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Additional Functions
Mode
Adj of ATR control Y-color target value
To adjust the offset of the ATR patch target value for Y.
When the target value determined upon initialization is changed, the TD ratio is also changed.
Fogging and density increase are alleviated when the value is smaller, and carrier adherence is
alleviated when it is larger.
When density failures, fogging, carrier adherence, etc. occur
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
3) Make 50 prints of approx. 10% image ratio (e.g. COPIER> TEST> PG> TYPE: 16) 4 times.
4) Execute auto gradation adjustment (full adjustment).
Execute the auto gradation adjustment first to increase the density. If you adjust the offset of the
target value, fogging might get worse.
-4 to 4
0
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation> Full Adjust
Adj of ATR control M-color target value
To adjust the offset of the ATR patch target value for M.
When the target value determined upon initialization is changed, the TD ratio is also changed.
Fogging and density increase are alleviated when the value is smaller, and carrier adherence is
alleviated when it is larger.
When density failures, fogging, carrier adherence, etc. occur
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
3) Make 50 prints of approx. 10% image ratio (e.g. COPIER> TEST> PG> TYPE: 16) 4 times.
4) Execute auto gradation adjustment (full adjustment).
Execute the auto gradation adjustment first to increase the density. If you adjust the offset of the
target value, fogging might get worse.
-4 to 4
0
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation> Full Adjust
Adj of ATR control C-color target value
To adjust the offset of the ATR patch target value for C.
When the target value determined upon initialization is changed, the TD ratio is also changed.
Fogging and density increase are alleviated when the value is smaller, and carrier adherence is
alleviated when it is larger.
When density failures, fogging, carrier adherence, etc. occur
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
3) Make 50 prints of approx. 10% image ratio (e.g. COPIER> TEST> PG> TYPE: 16) 4 times.
4) Execute auto gradation adjustment (full adjustment).
Execute the auto gradation adjustment first to increase the density. If you adjust the offset of the
target value, fogging might get worse.
-4 to 4
0
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation> Full Adjust
815