733-0002-05
Detection Description
Remedy
733-0F00-05
Detection Description
Remedy
733-0F01-05
Detection Description
Remedy
733-0F02-05
Detection Description
Remedy
733-9999-05
Detection Description
Remedy
743-0000-04
Detection Description
Remedy
743-0001-04
Detection Description
Remedy
744-0001-00
Detection Description
Remedy
Printer communication error
Signal error was detected after establishment of communication between the DC Controller PCB
and the Main Controller PCB.
[Related parts] R1.00
- Harnesses between the DC Controller PCB (UN1/J100, J101) and the Riser PCB (J2, J10)
- DC Controller PCB (UN1)
- Riser PCB
- Main Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Printer communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E733-0000 is generated.
It is not necessary to perform a remedy because the machine is automatically rebooted after log
collection.
Printer communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E733-0001 is generated.
It is not necessary to perform a remedy because the machine is automatically rebooted after log
collection.
Printer communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E733-0002 is generated.
It is not necessary to perform a remedy because the machine is automatically rebooted after log
collection.
Printer communication error
The Finisher connection information error was detected between the DC Controller PCB and the
Main Controller PCB.
Turn OFF and then ON the power
Communication error
The Reader Controller PCB detected a communication error between the Main Controller PCB
and the Reader Controller PCB.
[Related parts] R1.00
- Harness between the Reader Controller PCB (UN_BO1/J109) and the Riser PCB (J7)
- Reader Controller PCB (UN_BO1)
- Riser PCB
- Main Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx.
2 min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
DDI communication error
Software sequence error
[Remedy] Turn OFF and then ON the main power.
Language file error
The language file in HDD was not supported by the version of Bootable.
Reinstall the correct language file using SST or USB memory reinstall the entire software.