9. Turn the ITB Pressure Release Lever in the direction of the arrow to apply pressure.
CAUTION:
• When operating the ITB Pressure Release Lever, be sure to check that the Right Lower Cover is opened before the
operation.
• When applying pressure with the ITB Pressure Release Lever, be sure that the protrusion [2] on the handle [1] is
aligned with the triangle mark [3] on the lower side of the plate.
10. Install the ITB Cover [1] and tighten the 2 loosened screws [2].
CAUTION:
When installing the ITB Cover, be sure to push it to the left. If the pushing is insufficient, the plate is not inserted to the slit
of the ITB Cover, which may cause the damage of the sensor.
11. Close the Front Cover.
12. Close the Right Upper Cover.
13. Close the Right Lower Cover.

Removing the Drum Unit

■ Preparation
1. Pulling out the Process
■ Procedure
CAUTION:
Do not touch the surface of the Drum.
2x
Unit"Pulling out the Process Unit" on page 317