06-0012
-
A. Operation / B. Cause /
C. Remedy
09-0010
-
A. Operation / B. Cause /
C. Remedy
09-0011
-
A. Operation / B. Cause /
C. Remedy
09-0012
-
A. Operation / B. Cause /
C. Remedy
09-0013
-
A. Operation / B. Cause /
C. Remedy
Fixing memory detection alarm
Cause: Memory of the Fixing Film Unit could not be detected.
Measures:
1. Check the connection of the Fixing Unit, and check for any soiling or damage.
2. Check the connector of the Fixing Memory PCB (UN79).
3. Disconnect and then connect the connector (J122) of the DC Controller (UN1).
4. Replace the Fixing Film Unit.
5. Replace the DC Controller (UN1).
Drum memory detection error (Y)
Cause: The memory of the Drum Unit (Y) could not be detected.
Measures:
1. Remove and then install the Drum Unit (Y).
2. Check the contact point of the Drum Unit New/Old PCB (Y) (UN70).
3. Disconnect and then connect the connector (J608) of the Process Unit Relay PCB (UN20).
4. Disconnect and then connect the connector (J607) of the Process Unit Relay PCB (UN20).
5. Disconnect and then connect the connector (J306) of the Font Driver PCB (UN3).
6. Disconnect and then connect the connector (J301) of the Front Driver PCB (UN3).
7. Disconnect and then connect the connector (J111) of the DC Controller (UN1).
8. Replace the Drum Unit (Y).
9. Replace the Front Driver PCB (UN3).
Drum memory detection error (M)
Cause: The memory of the Drum Unit (M) could not be detected.
Measures:
1. Remove and then install the Drum Unit (M).
2. Check the contact point of the Drum Unit New/Old PCB (M) (UN71).
3. Disconnect and then connect the connector (J608) of the Process Unit Relay PCB (UN20).
4. Disconnect and then connect the connector (J607) of the Process Unit Relay PCB (UN20).
5. Disconnect and then connect the connector (J306) of the Font Driver PCB (UN3).
6. Disconnect and then connect the connector (J301) of the Front Driver PCB (UN3).
7. Disconnect and then connect the connector (J111) of the DC Controller (UN1).
8. Replace the Drum Unit (M).
9. Replace the Front Driver PCB (UN3).
Drum memory detection error (C)
Cause: The memory of the Drum Unit (C) could not be detected.
Measures:
1. Remove and then install the Drum Unit (C).
2. Check the contact point of the Drum Unit New/Old PCB (C) (UN72).
3. Disconnect and then connect the connector (J608) of the Process Unit Relay PCB (UN20).
4. Disconnect and then connect the connector (J607) of the Process Unit Relay PCB (UN20).
5. Disconnect and then connect the connector (J306) of the Font Driver PCB (UN3).
6. Disconnect and then connect the connector (J301) of the Front Driver PCB (UN3).
7. Disconnect and then connect the connector (J111) of the DC Controller (UN1).
8. Replace the Drum Unit (C).
9. Replace the Front Driver PCB (UN3).
Drum memory detection error (Bk)
Cause: The memory of the Drum Unit (Bk) could not be detected.
Measures:
1. Remove and then install the Drum Unit (Bk).
2. Check the contact point of the Drum Unit New/Old PCB (Bk) (UN73).
3. Disconnect and then connect the connector (J608) of the Process Unit Relay PCB (UN20).
4. Disconnect and then connect the connector (J607) of the Process Unit Relay PCB (UN20).
5. Disconnect and then connect the connector (J306) of the Font Driver PCB (UN3).
6. Disconnect and then connect the connector (J301) of the Front Driver PCB (UN3).
7. Disconnect and then connect the connector (J111) of the DC Controller (UN1).
8. Replace the Drum Unit (Bk).
9. Replace the Front Driver PCB (UN3).
649