COPIER > OPTION > IMG-FIX
FXS-TMP3
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXS-TMP4
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXS-TMP5
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXS-TMP6
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
Set ITOP control temp: heavy paper 2
To set the offset of ITOP control temperature for heavy paper 2 (129 to 150 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set ITOP control temp: heavy paper 3
To set the offset of ITOP control temperature for heavy paper 3 (151 to 163 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set ITOP control temp: thin paper 2
To set the offset of ITOP control temperature for thin paper 2 (52 to 59 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set ITOP control temperature: envelope
To set the offset of ITOP control temperature for envelope.
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5