Canon imageRUNNER ADVANCE C5500 Series Service Manual page 859

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > ADJUST > HV-PRI
OFSTACK2
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
■ HV-TR
COPIER > ADJUST > HV-TR
1TR-TGY
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
1TR-TGM
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
Adj Bk-color charging AC voltage: L-SPD
To adjust the offset of the charging AC voltage for Bk-color at low process speed.
The setting is applied to paper which paper weight is 129 g/m2 or more and coated paper.
As the value is changed by 1, the voltage is changed by 20 Vpp.
Decrease the value when image smear occurs, and increase the value when an image failure
(sand-like image) occurs.
- When image smear occurs
- When an image failure (sand-like image) occurs
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Use OFSTACK2 only when an image failure is not alleviated with DIS-TGK2. In such case, be sure
to change the setting value of DIS-TGK2 back to the original one. If both the settings are enabled,
an over discharge occurs.
-20 to 20
V
0
COPIER> ADJUST> HV-PRI> DIS-TGK2
20
Adj Y-clr pry trns ATVC tgt crrnt: H-SPD
To adjust the target current of primary transfer ATVC control for Y-color at high process speed.
Increase the value when low-voltage mottled image occurs, and decrease the value when fogging
occurs (especially in the 94 mm portion of the image leading edge).
By setting this item, primary transfer ATVC control is automatically executed during initial rotation
for next image formation and the setting value is reflected.
When an image failure due to the primary transfer occurs
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Execute 1ATVC-EX.
-50 to 50
uA
0
COPIER> FUNCTION> MISC-P> 1ATVC-EX
1
Adj M-clr pry trns ATVC tgt crrnt: H-SPD
To adjust the target current of primary transfer ATVC control for M-color at high process speed.
Increase the value when low-voltage mottled image occurs, and decrease the value when fogging
occurs (especially in the 94 mm portion of the image leading edge).
By setting this item, primary transfer ATVC control is automatically executed during initial rotation
for next image formation and the setting value is reflected.
When an image failure due to the primary transfer occurs
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Execute 1ATVC-EX.
-50 to 50
uA
0
COPIER> FUNCTION> MISC-P> 1ATVC-EX
1
845
8. Service Mode