Canon imageRUNNER ADVANCE C5500 Series Service Manual page 821

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > ADJUST > CCD
MTF-S12
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
Amount of Change per
Unit
DFCH2K2
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
DFCH2K10
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
DFCH-K2
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
MTF value 12 entry:vert scan, back side
To enter the setting value 12 for MTF filter coefficient calculation in vertical scanning direction.
Enter the value of service label on the Reader.
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
20 to 85
50
COPIER> FUNCTION> CCD> MTF-CLC
1
Complex chart No.2 data (B&W) entr: frt
To derive the front/back side linearity, enter the B&W data on the front side of No.2 image in DADF
complex chart.
Enter the value of service label on the Reader.
When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
1 to 2550
2000
1
Complex chart No.10 data (B&W) entr: frt
To derive the front/back side linearity, enter the B&W data on the front side of No.10 image in
DADF complex chart.
Enter the value of service label on the Reader.
When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 2550
0
1
Complex chart No.2 data (B&W) entr: bck
To derive the front/back side linearity, enter the B&W data on the back side of No.2 image in DADF
complex chart.
Enter the value of service label on the Reader.
When replacing the Reader Controller PCB/clearing RAM data
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
1 to 2550
2000
1
807
8. Service Mode

Advertisement

Table of Contents
loading