Canon imageRUNNER ADVANCE C5500 Series Service Manual page 982

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > OPTION > IMG-FIX
FXS-T001
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXS-T002
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXS-T003
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
FXS-T004
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
Set ITOP control temp: thin paper 1
To set the offset of ITOP control temperature for thin paper 1 (60 to 63 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set ITOP control temp: plain paper 3
To set the offset of ITOP control temperature for plain paper 3 (91 to 105 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set ITOP control temp: heavy paper 4
To set the offset of ITOP control temperature for heavy paper 4 (164 to 180 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set ITOP control temp: heavy paper 5
To set the offset of ITOP control temperature for heavy paper 5 (181 to 220 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
968
8. Service Mode

Advertisement

Table of Contents
loading

Table of Contents