Canon imageRUNNER ADVANCE C5500 Series Service Manual page 986

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

COPIER > OPTION > IMG-FIX
TMP-TB03
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TB04
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TB05
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
Set fixing control temp: heavy paper 5
To set the offset of fixing control temperature for heavy paper 5 (181 to 220 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on heavy paper 5
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temp: plain paper 3
To set the offset of fixing control temperature for plain paper 3 (91 to 105 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on plain paper 3
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temp: heavy paper 6
To set the offset of fixing control temperature for heavy paper 6 (221 to 256 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on heavy paper 6
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5