Canon imageRUNNER ADVANCE C5500 Series Service Manual page 912

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

■ DBG-LOG
COPIER > FUNCTION > DBG-LOG
LOG2USB
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
LOG2SRVR
2
LOG-TRIG
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Related Service Mode
HIT-STS
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Related Service Mode
SYSLOG
2
DEFAULT
2
Detail
Use Case
Adj/Set/Operate Method
LOG-DEL
2
Detail
Use Case
Adj/Set/Operate Method
HIT-STS2
2
Storage of debug log to USB memory
To store a set of debug logs to the USB memory at the error occurrence.
A type of log to be collected is set in LOG-TRIG.
If there is a debug log which has been automatically saved, it is archived at this time.
Required time differs according to the device conditions and volume of log data.
When analyzing the cause of a problem
1) Install the USB memory.
2) Select the item, and then press OK key.
- Wait until the machine recognizes the USB memory (approx. 10 sec.).
- During the data transfer ("ACTIVE" display), do not turn OFF the power/remove the USB memory/
use the screen for operations.
During operation: ACTIVE, At normal termination: OK!, At abnormal termination: NG
COPIER> FUNCTION> DBG-LOG> LOG-TRIG
For R&D
Set of debug log storage condition
To set the conditions (timing, types, etc.) to automatically store the debug logs (stored as an archive
file).
By reading the operation setting file of the setting value from the Main Controller, the conditions
written in the file are set.
When setting a new condition is necessary, read the operation setting file provided by R&D from
the USB memory.
- When changing the conditions of debug log to automatically store
- When setting a new condition
Enter the setting value, and then press OK key.
0 to 99999
COPIER> FUNCTION> DBG-LOG> LOG2USB, LOG2SRVR
Display of debug log state
To display whether archive file of the debug log which is matched with the conditions set in LOG-
TRIG exists or not.
When checking the debug log automatically saved
Select the item, and then press OK key.
At normal state: OK, At failure occurrence: --
COPIER> FUNCTION> DBG-LOG> LOG-TRIG
For R&D
Reset of debug log setting
To clear all debug log settings and return to the state before debug log collection operation.
- When returning the device in which analyzing the cause of a problem was completed
- When resetting the debug log settings
Select the item, and then press OK key.
Clearing of debug logs
To delete the debug log file.
The debug log setting is not reset.
When clearing the debug log
Select the item, and then press OK key.
For R&D
898
8. Service Mode