Canon imageRUNNER ADVANCE C5500 Series Service Manual page 530

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

197-2005-05
Detection Description
Remedy
199-0101-05
Detection Description
Remedy
199-0102-05
Detection Description
Remedy
199-0103-05
Detection Description
Remedy
199-0104-05
Detection Description
Remedy
199-0201-05
Detection Description
Remedy
199-0202-05
Detection Description
Remedy
199-0203-05
Detection Description
Remedy
Serial communication error
A communication error between the DC Controller PCB and the Feed/Drum Driver PCB was
detected.
[Related parts] R1.00
- Harness between the DC Controller PCB (UN1/J170 and J172) and the Feed/Drum Driver PCB
(UN2/J202 and J203)
- Feed/Drum Driver PCB (UN2)
- DC Controller PCB (UN1)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Error in high voltage sequence (Y)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
Error in high voltage sequence (M)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
Error in high voltage sequence (C)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
Error in high voltage sequence (K)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
Error in high voltage sequence (Y)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
Error in high voltage sequence (M)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
Error in high voltage sequence (C)
Error for collecting log.
[Remedy] Collect debug log and contact to the sales company.
[Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled
as an error.
516
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading