■ Procedure
1. Clean the Fixing Shutter Cover [2] with lint-free paper [1] moistened with alcohol.
Cleaning the Fixing Separation Guide
■ Preparation
1. Open the Right Lower Cover and the Right Upper Cover.
2. Removing the Fixing
■ Procedure
CAUTION:
Be sure not to touch the Film Unit or the Pressure Roller during installation/removal.
1. Change the direction of the Fixing Unit. (Place it so that the Drawer Connector [1] is on the top side.)
2. Remove the PCB [2].
• 1 Screw [3]
[1]
[2]
Unit"Removing the Fixing Unit" on page 360
1x
[1]
[3]
[2]
366