• When the left side of the trailing edge of image is distorted
Turn the screw counterclockwise.
Feed direction
• When the right side of the trailing edge of image is distorted
Turn the screw clockwise.
Feed direction
■ Fixing alignment adjustment
Adjustment is possible by loosening the screw located as shown in the figure below and moving the Adjustment Plate up and
down. Check the position of the Adjustment Plate before adjustment.
The range which can be adjusted by this adjustment is maximum of approx. 0.3 mm. (Differs according to the paper type)
The right side of the trailing edge of image is distorted.
The left side of the trailing edge of image is distorted.
Symptom
Move the Adjustment Plate up.
Move the Adjustment Plate down.