COPIER > OPTION > IMG-FIX
TMP-TB06
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TB07
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TB08
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
Set fixing control temp: heavy paper 7
To set the offset of fixing control temperature for heavy paper 7 (257 to 300 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on heavy paper 7
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fix control temp: 1-side coat ppr 3
To set the offset of fixing control temperature for 1-sided coated paper 3 (221 to 256 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on 1-sided coated paper 3
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fix control temp: 2-side coat ppr 1
To set the offset of fixing control temperature for 2-sided coated paper 1 (106 to 163 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on 2-sided coated paper 1
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5