Cleaning The Fixing Shutter Cover - Canon imageRUNNER ADVANCE C5500 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

10. After replacing the Film Unit, install the Fixing Unit, and then execute "Settings/Registration > Adjustment/
Maintenance > Adjust Image Quality > Auto Adjust Gradation".
CAUTION:
Be sure to check that the Fixing Separation Guide [1] is installed properly.
Examples of improper installation
• Illustration at the center: The Fixing Separation Guide is placed on the rib [A].
• Illustration at the right: The Fixing Separation Guide is installed in opposite direction.
Checking method:
• After installing the Fixing Separation Guide, swing the guide with your finger. If it is installed properly, it is stable. If not,
it becomes wobbly.
• When installing the Leaf Spring while the guide is not installed properly, the spring will be expanded awkwardly.

Cleaning the Fixing Shutter Cover

■ Preparation
1. Open the Right Lower Cover and the Right Upper Cover.
2. Removing the Fixing
3. Removing the Film
Unit"Removing the Film Unit" on page 361
[1]
Unit"Removing the Fixing Unit" on page 360
[A]
365
4. Disassembly/Assembly

Advertisement