Canon imageRUNNER ADVANCE C5500 Series Service Manual page 1149

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

Settings] > [Register Correction Pattern], and press
[Yes].
CAUTION:
It is required that auto gradation adjustment has been
executed.
4. Select the destination for registration, and press
[Next].
5. Select the paper which is used by the user and press
[Next].
CAUTION:
• Select the paper used for auto gradation
adjustment.
• If paper has been registered for auto gradation
adjustment, select the registered paper.
6. Select the paper source where paper which is used
by the user is loaded and press [OK].
7. Press [Start Printing].
8. Set the output image on the Copyboard and press
[Start Scanning].
9. If there are 2 or more papers which either was used
for auto gradation adjustment or has been
registered, repeat steps 3 to 8 as necessary. At that
time, be sure to register each paper to different
destination. (Up to 4 papers can be registered.)
Execute the ITB Equilibrium
Position Detection
1. Check that the main body is in standby state.
2. Execute the ITB Equilibrium Position Detection.
Approx. 3 to 4minutes
• Service Mode (Level 1) > COPIER > FUNCTION >
MISC-P > ITB-INIT
3. Check that the value of the following service mode
(Level 1) is "-350 to +350".
• COPIER > DISPLAY > MISC > ITB-POS
• COPIER > DISPLAY > MISC > ITB-POS2
4. If the value of service mode is out of range, perform
the [ITB Alignment Adjustment].
NOTE:
Since this product is not affected by the tilt of floor,
adjustment of the adjuster height is not valid. Therefore, if
it is out of the range, perform "ITB alignment adjustment".
■ ITB Alignment Adjustment
1. Turn OFF the main power switch of the host
machine.
2. Be sure that Control Panel Display and Main Power
Lamp are both turned OFF, and then disconnect the
power plug.
3. Open the Front Cover and remove the ITB Cover.
• 2 Screws (Loosen)
2x
4. Remove the ITB Motor [1].
• 1 Connector
• 4 Screws
1x
5. Loosen the 3 screws, and rotate the ITB Motor
Support Plate clockwise or counterclockwise.
• Moving it by 1 unit (0.5 mm) changes the values of
ITB-POS and ITB-POS2 by approx. 250.
1135
9. Installation
4x

Advertisement