Canon imageRUNNER ADVANCE C5500 Series Service Manual page 974

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

■ IMG-FIX
COPIER > OPTION > IMG-FIX
FX-S-TMP
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TBL2
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TBL3
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
Set ITOP control temp: plain paper 1
To set the offset of ITOP control temperature for plain paper 1 (64 to 75 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
When uneven gloss occurs on the leading edge (94 mm)
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temp: heavy paper 1
To set the offset of fixing control temperature for heavy paper 1 (106 to 128 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on heavy paper 1
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temp: heavy paper 2
To set the offset of fixing control temperature for heavy paper 2 (129 to 150 g/m2).
As the value is changed by 1, the temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When offset/fixing failure occurs on heavy paper 2
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
960
8. Service Mode

Advertisement

Table of Contents
loading

Table of Contents