713-0022-05
Detection Description
Remedy
713-0030-05
Detection Description
Remedy
Finisher communication error
An undefined error was detected consecutively in communication between the host machine and
the finisher.
a. STAPLE/BOOKLET FINISHER-Y1
[Related parts] R1.00
- Harnesses connecting the DC Controller PCB (UN1/J110), the Relay Path Unit and the Finisher
Controller PCB
- Harnesses connecting the Relay PCB (UN5/J403), the Relay Path Unit and the Finisher Controller
PCB
- DC Controller PCB (UN1)
- Relay PCB (UN5)
- Relay Path Unit
- Finisher Controller PCB
b. INNER FINISHER-H1
[Related parts]
- Harness between the DC Controller PCB (UN1/J110) and the Finisher Controller PCB
- Harness between the Relay PCB (UN5/J403) and the Finisher Controller PCB
- DC Controller PCB (UN1)
- Relay PCB (UN5)
- Finisher Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference]
- Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and
restore the backup data after the replacement so the data may be able to be protected.
Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
- After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when
Replacing the Parts" in the Service Manual for the Finisher.
Finisher communication error
An initialization error was detected in communication between the host machine and the finisher.
a. STAPLE/BOOKLET FINISHER-Y1
[Related parts] R1.00
- Harnesses connecting the DC Controller PCB (UN1/J110), the Relay Path Unit and the Finisher
Controller PCB
- Harnesses connecting the Relay PCB (UN5/J403), the Relay Path Unit and the Finisher Controller
PCB
- DC Controller PCB (UN1)
- Relay PCB (UN5)
- Relay Path Unit
- Finisher Controller PCB
b. INNER FINISHER-H1
[Related parts]
- Harness between the DC Controller PCB (UN1/J110) and the Finisher Controller PCB
- Harness between the Relay PCB (UN5/J403) and the Finisher Controller PCB
- DC Controller PCB (UN1)
- Relay PCB (UN5)
- Finisher Controller PCB
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference]
- Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and
restore the backup data after the replacement so the data may be able to be protected.
Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
- After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when
Replacing the Parts" in the Service Manual for the Finisher.