013-0002-05
Detection Description
Remedy
014-0001-05
Detection Description
Remedy
020-0124-05
Detection Description
Remedy
020-0134-05
Detection Description
Remedy
020-01A8-05
Detection Description
Remedy
Waste Toner Feed Motor error
Rotation error of the Waste Toner Feed Motor was detected consecutively.
[Related parts] R1.00
- Harnesses connecting the Front Driver PCB (UN3/J306), the Drawer Unit (J755) and the Waste
Toner Feed Motor (M26/J6111)
- Waste Toner Feed Motor (M26)
- Waste Toner Container
- Front Driver PCB (UN3)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check for toner amount and clogging in the Waste Toner Container and the Waste Toner Feed
Pipe.
2. Check/replace the related harness/cable, connector and parts.
Fixing Motor error
Lock error of the Fixing Motor was detected.
[Related parts] R1.00
- Harness between the Feed/Drum Driver PCB (UN2/J215) and the Fixing Motor (M21/J6084)
- Fixing Motor (M21)
- Film Assembly
- Feed/Drum Driver PCB (UN2)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1 Check that the Fixing Assembly is properly installed.
2. Check/replace the related harness/cable, connector and parts.
ATR output error
The ATR Patch (Y) detected that the output value (SigD) was below the lower limit at initialization
of the Developing Assembly.
[Related parts] R1.00
- Drum Unit
- Developing Assembly (Y)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check that the Developing Assembly and the Drum Unit are properly installed.
2. Remove soiling on the exposure window and the Drum Unit.
3. Replace the Developing Assembly and the Drum Unit.
ATR output error
The ATR Patch (Y) detected that the output value (SigD) exceeded the upper limit at initialization
of the Developing Assembly.
[Related parts] R1.00
- Drum Unit
- Developing Assembly (Y)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check that the Developing Assembly and the Drum Unit are properly installed.
2. Remove soiling on the Drum Unit.
3. Replace the Developing Assembly and the Drum Unit.
ATR output error
The ATR Sensor (Y) detected that the output value was below the lower limit during printing.
[Related parts] R1.00
- Harnesses connecting the Process Unit Relay PCB (UN20/J609), the Relay Connector
(J5093/5P) and the ATR Sensor (Y) (TS5/J6114)
- Developing Assembly (Y)
[Remedy] Check/replace the related harness/cable, connector and parts.