Stop during axes group operation
This section explains each stop cause.
Stop cause occurrence in the configuration axis
The following shows axes group operation when a stop cause of the configuration axis occurs.
Stop cause occurrence axis
Caus
Stop cause
e No.
1
"Forced stop input" is OFF
2
Drive unit power supply is OFF
Drive unit network disconnection detection
Drive unit error
Forced stop input to the drive unit
Enable of MC_Power is FALSE
ServoON of MC_Power is FALSE
(When AxisName.Pr.StopMode_ServoOff
is "4:
ServoOffAfterImmediateStop")
3
Hardware stroke limit upper/lower limit
error occurrence
4
CPU module error occurrence
PLC READY [Y0] is OFF
5
Software stroke limit upper/lower limit error
occurrence
6
Axis error detection
7
Execute of MC_Stop is TRUE
8
"Stop signal" of external input signal is
TRUE
*1 The servo OFF is executed in the driver side and the axis immediately stops, and also the motion side command is stopped.
*2 If a single axis FB is executed during axes group operation, an axis error will occur and the single axis FB will be disabled. For details,
refer to the following.
Page 153 Axis error
4 START AND STOP
150
4.4 Stop
Axis status
Stop
at stop
process
cause
occurrence
(AxisName.
Md.AxisStat
us)
1: ErrorStop
Immediate
*1
stop
1: ErrorStop
1: ErrorStop
Based on the
axes group
stop process
1: ErrorStop
1: ErrorStop
1: ErrorStop
*2
1: ErrorStop
No change
Axes group
Axes group
Stop process
status
(AxesGroup
Name.Md.Gr
oupStatus)
1:
Stop cause occurrence axis: Immediate stop
GroupErrorSto
Other configuration axes: Axes group
p
deceleration stop/immediate stop (Follows
AxesGroupName.Pr.StopMode_ErrorInGroup)
Axes group deceleration stop/immediate stop
(Follows
AxesGroupName.Pr.StopMode_General)
No change
Axes group deceleration stop/immediate stop
(Follows
AxesGroupName.Pr.StopMode_General)